ASTM C1244 PDF

ASTM C() Standard Test Method for Concrete Sewer Manholes by the Negative Air Pressure (Vacuum) Test Prior to Backfill Paperback – April 1. ASTM A/AMa Testing Mechanical Splices for Steel Reinforcing Bars .. ASTM C Concrete Sewer Manholes by the Negative Air Pressure. This standard is issued under the fixed designation C; the 1 This test method is under the jurisdiction of ASTM Committee C13 on.

Author: Julmaran Akikree
Country: Spain
Language: English (Spanish)
Genre: Medical
Published (Last): 5 April 2013
Pages: 284
PDF File Size: 15.30 Mb
ePub File Size: 18.71 Mb
ISBN: 397-2-39465-271-5
Downloads: 38974
Price: Free* [*Free Regsitration Required]
Uploader: Danos

If the document is revised or amended, you will be notified by email. Please first log in with a d1244 email before subscribing to alerts. Significance and Use This is not a routine test.

Please first verify your email before subscribing to alerts. You can download and open this file to your own computer but DRM prevents opening this file on another computer, including a networked server.

This test method is used for testing concrete manhole sections asym mortar, mastic, or gasketed joints. Please first verify your email before subscribing to alerts.

The test and criteria have been widely and successfully used in testing manholes. Thank you for the comment Taylor. Testing after backfilling provides a degree of certainty that a watertight system has been installed. Remember me for one month. Vacuum testing is a quick, safe and practical way to validate manhole system integrity. You may delete a document from your Alert Profile at any time. The user of this test method is advised that no correlation has been found between vacuum air and hydrostatic tests.

Subscription pricing is determined by: Vacuum testing a manhole system that is already subjected to hydrostatic pressure may exceed the design limits of critical flexible connectors, leading to a system failure. If ground water is present, use the following information to determine if a reduction in vacuum pressure is warranted: Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

  CARDIOPATHIE DU POST PARTUM PDF

Search book title Enter keywords for book title search. If ground water is present, use the following information to determine if a reduction in vacuum pressure is warranted:. Note 1 – Vacuum test criteria presented in this test method are similar to those in general use.

Copyright Compu-tecture, Inc. So in your example, we would round the depth of bury up to 16 feet, meaning we would need asgm mercury to hold for at xstm 40 seconds. When to vacuum test Many codes and specifications require that a vacuum test be performed after the manhole has been installed and backfilled. Standards Subscriptions from ANSI provides a money-saving, multi-user solution for accessing standards.

As the voice of the U. For more information on precast concrete manholes, please contact NPCA at or visit www. With this information, you can determine that the theoretical in-place loads experienced by the deepest connector as outlined in the following example. Disclaimer The above information is intended solely for use by professional personnel who can evaluate the significance and limitations of this information and accept total responsibility for its application.

Add to Alert PDF. Standards Subscriptions from ANSI provides a money-saving, multi-user solution for accessing standards. Please first log in with a verified email before subscribing to alerts.

Many people do not fully understand the effects of vacuum testing backfilled manhole systems in the presence of ground water.

Vacuum Testing Precast Concrete Manholes

Depth to water table 2. Please first log in with a verified email before subscribing to alerts. This standard is also available to be included in Standards Subscriptions. Proceed to Checkout Continue Shopping. Users are hereby cautioned that misuse or misapplication of the test criteria contained herein can cause permanent damage to the system being c1424. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

It asym the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. You can download and open this file to your own computer but DRM prevents opening this file on aastm computer, including a networked server. Note 2 – The user of this test method is advised that no correlation has been found between vacuum air and hydrostatic tests. Vacuum testing backfilled manhole systems is not recommended, especially in the presence of ground water.

  ISO 11898-3 PDF

This test method is used sstm testing concrete manhole sections utilizing mortar, mastic, or gasketed joints.

Adjusting vacuum pressure Most flexible connectors have a pressure rating of only 10 psi when deflected, which is fairly common in a field installation; therefore we will use the more conservative 10 psi c124 rating as a base point. This standard is not included in any packages.

ASTM-C, –

If the manhole fails the initial test, it may be repaired by an approved method until a satisfactory test is obtained. To determine the actual loads induced on a backfilled structure, use the following information in addition to the actual in-place soil properties to properly calculate the effective stress at the critical location.

This standard is not included in wstm packages. There were no books found for the applied search filters. Therefore, to be more conservative, it is recommended that you round aetm depth of bury up to the nearest measurement on the table. The test and criteria have been widely asrm successfully used in testing manholes. FORMAT Single User Subscription Site License Subscription BOOKS All Books PACKAGES All Packages EDITION to PUBLISHER. Note 2—The user of this test method is advised that no correlation has been found between vacuum air and hydrostatic tests.

Note 2The user of this test method is advised that no correlation has been found between vacuum air and hydrostatic tests.

In your example, if we round down to a foot depth of bury, we would need the mercury to hold for at least 35 seconds.